# How to Fix a Running Toilet: Two Valves and One Pencil Mark

Why a leaking flapper sounds exactly like a broken fill valve, and how a pencil mark on the tank wall plus a closed supply stop tells you which part to buy

> toilet repair · plumbing basics · About 7 min · Nov 22

## Key points

1. A running toilet has two possible faults: the flush valve seal letting water out into the bowl, or the fill valve failing to shut the supply off. Both sound the same, because in both cases water ends up going down the overflow tube into the bowl.
2. A leaking flapper disguises itself as a fill valve problem, because the fill valve is the part that refills the tank and the part you hear, so replacing it leaves the real leak in place.
3. Mark the settled water level on the tank wall with a pencil, close the supply stop, and wait twenty to thirty minutes. A falling level means water is leaving through the flush valve, since nothing can enter while the supply is off. An unchanged level means the fill valve is at fault.
4. If the level drops and settles near the flapper, the seal is the leaker; if it keeps dropping toward the tank bottom, the seat or the flush valve body is damaged.
5. If the fill valve is the problem, lower the float so it shuts off roughly half an inch to one inch below the top of the overflow tube before buying anything. Water that still climbs past that point means debris, a dragging float, or a worn valve.
6. Free checks come first on the flush side: chain slack of one to two links, a binding handle, mineral crust on the seat, the refill tube clipped above rather than inside the overflow, and rubber that streaks black on your fingers.
7. Fix one fault and retest, because both can be present and a flapper leak can mask a fill valve that never closes.

---

A running toilet is the one household repair where the sound misleads you. Search "how to fix a running toilet" and you get a list that starts with the flapper and then moves on to the fill valve. Most people work down that list in the wrong order: they replace the fill valve first, because the fill valve is the part they can hear running, and the noise comes back a week later. A pencil and half an hour of waiting will tell you which of the two parts you actually need. First the tank has to make sense.

A toilet tank is a bucket with one inlet and one outlet, and each has its own shutoff. The outlet sits at the bottom middle: a wide opening into the bowl, closed by a rubber seal. On most toilets that seal is a flapper, the hinged flap on the end of a chain; on newer 1.28-gallon models it is a seal inside a canister or tower. Either way, it is the only thing holding water in the tank between flushes. The inlet is the fill valve on the left, fed by the supply line and controlled by a float that rides on the water. When the level drops, the float drops and the valve opens. When the water reaches a set height, the float has risen far enough to close it again.

Then there is the part with no valve at all. The overflow tube is an open-ended standpipe rising out of the flush valve and running straight down into the bowl. It is a spillway: if the fill valve fails to close, the water rises past the set point, reaches the open top of that tube, and pours into the bowl instead of over the tank rim onto your floor. That is also why a toilet that keeps running is nearly always one with water going down that tube, since the overflow is the only route from a full tank to the drain that doesn't involve a flush.

The confusion starts here. Suppose the flapper has gone soft and lets water seep past into the bowl. The tank slowly drains, but a draining tank is not what you hear. The fill valve is what you hear. The level drops a fraction, the float drops with it, the valve opens, refills to the set point, closes. A slow seep gives you a short hiss every ten or twenty minutes. A big one gives you one continuous sound. Either way the noise is the fill valve doing exactly its job, which is why people blame it. Fluidmaster, which makes these valves, calls this out as a standard misdiagnosis: a slightly leaking flush valve produces a "pulsing" fill valve, and the valve gets replaced for nothing [3].

A fill valve that won't shut off makes almost the same racket from the other direction. Water keeps arriving, the level climbs to the overflow rim, spills down the tube, and keeps spilling. Running sound, faint ripple in the bowl. Same symptom, opposite end of the tank.

So the symptom cannot separate the two. What separates them is the direction water crosses the tank: arriving through the inlet when it shouldn't, or leaving through the outlet when it shouldn't. A pencil will measure that.

Flush, let the tank finish refilling, and mark the water level on the inside tank wall right where the surface sits. Then close the supply stop, the small oval handle on the wall or floor behind the toilet, turning it clockwise until it stops. If it won't move, close the house main rather than forcing it. Wait twenty to thirty minutes. A slow flapper leak can hide for a while [2], so give it a couple of hours if you have them.

If the line has dropped, you have your answer. With the supply closed, nothing can enter the tank, so the only way the level goes down is through the flush valve into the bowl, and the fill valve was never the problem. How far it falls adds detail. A level that settles around the flapper and stops means the seal is weeping; one that keeps dropping toward the bottom of the tank means the seat the seal presses against, or the valve body itself, is damaged, and no new flapper will fix it [2].

If the mark is untouched, the outlet is holding and the fault is on the supply side. Open the stop and watch: the level climbs past your mark, reaches the overflow rim, and starts trickling down the tube.

Before buying a fill valve, make one free distinction. The correct shutoff point is roughly half an inch to one inch below the top of the overflow tube [1]. If the float is set above that, the valve is doing precisely what it was told, and the fix is to lower the float a turn or a notch. If the shutoff point is already inside that band and the water still climbs past it, the valve isn't closing: grit in the cap or diaphragm, a float dragging against the tank wall or the flush valve body, or a worn valve [1]. Debris is especially common right after any plumbing work, when shutting the supply off and on frees sediment that was sitting quietly in the pipes.

Fix one thing, then retest. A toilet can have both faults at once, and a flapper leak holds the level down, which hides a fill valve that never closes. The second problem only shows up once the first is gone.

On the flush side, a few checks cost nothing. The chain from the handle to the flapper should hang with about one to two links of slack: too tight and it holds the flapper a hair off the seat, which is the toilet you have to jiggle the handle on; too long and it can catch under the flapper and prop it open [2]. A loose handle keeps tension on the chain the same way. Run a finger around the valve seat, since mineral crust there keeps any flapper from sealing. Look at the thin refill tube from the fill valve, which should be clipped to the top of the overflow tube rather than stuffed down inside it. Then rub the flapper itself: if your fingers come away with black streaks, the rubber has broken down and is due for replacement, which most water utilities suggest doing every five years or so [4].

If you just want to know whether water is escaping into the bowl without kneeling by the stop valve, the dye test answers it in ten minutes. Drop food coloring or a dye tablet into the tank, don't flush, and look at the bowl. Color in the bowl means the tank is leaking past the flush valve [5].

![Green dye dropped into the tank appearing in the bowl with no flush is direct evidence that the flush valve seal is leaking](https://www.denverwater.org/sites/default/files/styles/inline_image_700px_wide/public/2023-03/2%20green%20in%20bowl.jpg?itok=P4p3y2r-)

What you carry home follows from the test. A flapper is a few dollars and is the most common cause of a running toilet [4], so take the old one to the store, because they come in different shapes and a mismatched one won't seat. A canister or tower toilet needs its own brand-specific seal instead. A fill valve costs more, so arrive at the store for one only after the float adjustment has failed to stop the water.

The stakes are small in parts and large in water. The EPA estimates a leaking toilet can waste about 200 gallons a day [6], which is a real line on a water bill and a real reason not to leave this for later. But the shape of the problem is what's worth keeping: the tank holds water only because two shutoffs hold, one at the inlet and one at the outlet, and every running toilet is one of them failing. The pencil mark answers one question, whether the water left through the outlet or kept arriving through the inlet, and the part to buy follows from that. It is the same logic as [a dripping faucet](https://eulore.ai/articles/how-to-fix-a-leaky-faucet-d92b5c0f), where the location of the water, not the sound of it, picks the part.

```mermaid
flowchart LR
  A["Toilet runs with no flush"] --> B["Flush, let tank refill, mark water line with pencil"]
  B --> C["Close supply stop, wait 20-30 min"]
  C --> D{"Water line dropped below the mark?"}
  D -->|"Yes"| E["Water leaving through the flush valve"]
  E --> F["Clean the seat, replace flapper or canister seal"]
  D -->|"No"| G["Water arriving through the fill valve"]
  G --> H{"Still climbs past the overflow rim after lowering the float?"}
  H -->|"No, it was set too high"| I["Set shutoff 1/2-1 in below overflow top"]
  H -->|"Yes"| J["Clean the fill valve cap or replace the valve"]
```

## Mind map

```mermaid
flowchart LR
  T["Running toilet: two shutoffs in one bucket"] --> O["Outlet: flush valve with flapper or canister seal"]
  T --> I["Inlet: fill valve with float"]
  T --> V["Overflow tube: spillway into the bowl"]
  O --> L["Leak hides behind the fill valve's noise"]
  I --> S["Never closes: water spills down the overflow"]
  L --> P["Pencil mark plus supply off"]
  S --> P
  P --> PO["Level fell: fix flush valve seal or seat"]
  P --> PI["Level held: adjust float, then clean or replace fill valve"]
  PO --> R["Fix one, retest: both can fail at once"]
  PI --> R
```

## Glossary

- Flush valve：the outlet at the bottom of the tank, held closed by a rubber seal (a flapper, or a canister seal on newer toilets); it opens during a flush and must seal again afterward.
- Fill valve：the inlet on the left of the tank, controlled by a float; it opens when the level drops and must close itself at a set height.
- Overflow tube：the open-topped standpipe rising out of the flush valve and leading into the bowl, a spillway that sends excess water to the drain instead of onto the floor.
- Valve seat：the rim the flapper or canister seal presses against; mineral buildup or damage there makes even a new seal weep.
- Pencil mark test：marking the tank's water level, shutting off the supply, and watching whether the level falls, which shows whether water is escaping through the outlet or arriving through the inlet.
- Supply stop：the small shutoff valve on the wall or floor behind the toilet, used to isolate the tank for the test and for repairs.

## Sources

1. [City of Portland: How to find and fix a toilet leak — tank parts, correct water level and float adjustment](https://www.portland.gov/water/water-efficiency-programs/fixatoiletleak)
2. [Korky: How to Fix a Running Toilet — pencil mark test, reading how far the level falls, chain slack, canister seals](https://www.korky.com/toilet-repair-help/running-toilet)
3. [Fluidmaster: The Little Guide Book of Toilet Repairs — the two tank valves and the pulsing-fill-valve misdiagnosis](https://www.fluidmaster.com/wp-content/uploads/2020/11/Pocket-Toilet-Repair-Guide_web.pdf)
4. [Saving Water Partnership: Toilet Leaks — worn flappers as the usual cause and five-year replacement advice](https://www.savingwater.org/indoors/toilets/toilet/)
5. [Denver Water: Stop your running toilet during Fix a Leak Week — dye test procedure and float arm misadjustment](https://www.denverwater.org/tap/stop-your-running-toilet-during-fix-leak-week)
6. [EPA WaterSense: Indoor Water Use in the United States — a leaky toilet can waste about 200 gallons a day](https://www.epa.gov/sites/default/files/2017-03/documents/ws-facthseet-indoor-water-use-in-the-us.pdf)

---